<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15251</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: plate not detected on load ramp
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Put a plate on the load ramp and click the "RESUME" button.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
If the above action does not solve the problem, then the load ramp sensor may not be
working properly. Use "set al lps 0" in diagnostic monitor to bypass the sensor to get
the customer going and arrange for field service.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The operator did not place a plate on the load ramp before hitting the load button.
</Cause>
<Cause>
The load plate sensor is damaged or misaligned.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_lps.xml</LinkAddress><LinkTitle>NVS: al lps</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:58 2008 PST
</Updated>